The Multimotor Model:
This model is a Dual control type Water level controller system which can control Sump motor as well as Borewell motor with Automatic Changeover Technology and Built-in advanced 'Pumpset Protection Circuitry'. This model comes with Two Year Guarantee.
The Technical Specifications:
| Description | Single Phase | Three Phase | |
| Operating Voltage. | 230V 50 Hz AC. | 440V 50 Hz AC. | |
| System Operating Voltage. | 12V DC. | ||
| Sensing Voltage. | 1.5V, 100 Hz AC signal. | ||
| Sensing Current. | 20 micro Amp. | ||
| Power Contactor Rating. | 30A Load Current. | 10A for Coil Control. | |
| Operating Switch Rating. | 20A. | 6A. | |
| Low Voltage cut-off at. | 170V. | 340V. | |
| Auto Reset at. | 180V. | 370V. | |
| Surge Voltage delay. | 15 Sec. | ||
| Pump Changeover Delay. | 15 Sec. | ||
| Power Consumption | 0.08 Unit Per day. | ||
| Visual Indications. |
|
||
| Enclosure. | Power Coated MS Sheet Metal. | ||
| Dimensions ( L X B X H ) | 11 inch X 7 inch X 3.5 inch. | GO BACK | |